TOFD ultrasonic testing (UT) is typically used in conjunction with a a phased-array application as a rapid screening tool for the detection and sizing of circumferential- and axial-weld imperfections. In ToFD ultrasonic testing, the ToFD NDT setup involves placing two transducers on opposite sides of the area to be inspected. Sound waves are then refracted into the specimen at angles appropriate to component thickness.